Antaira’s LNP-0500 is a smart 5-port Industrial Unmanaged Ethernet Switch supporting IEEE-802.3at compliance (Power-over-Ethernet Plus) on ports 1 to 4. The switch is classified as power sourcing equipment (PSE), and when used in this way, LNP-0500 enables centralization of the power supply and provides up to 30 watts of power per port. LNP-0500 can be used to power IEEE 802.3af or 802.3at compliant power devices (PD), eliminating the need for additional wiring, and support IEEE 802.3/802.3u/802.3x with 10/100BTx, full or half duplex, MDI/MDI-X auto sensing to provide an economical solution for the Industrial Ethernet Network. In addition, the Network Broadcast Storm Protection and built-in relay warning function alerts network engineers when power failures or port breaks occur.
- Network broadcast storm protection
- 4-Port IEEE 802.3at compliant PoE+ Function with 30W/Port
- 1-Port 10/100Tx Fast Ethernet
- Supports Auto MDI/MDI-X Function
- Store-and-Forward Switching Architecture
- 2K MAC Address Table
- Surge Protection: 2,000 VDC support
- ESD Protection: 6,000 VDC support
- Redundant Power Input Design - 12~36VDC
- Built-in 1 relay output for Port Break Alarm
- IP30 Rugged Aluminum Case Design
- DIN-Rail and Wall Mount support
- Operating Temperature range EOT: -40° to 75° C
- 5-Year Warranty
- LNP-0500-24-T
- Mounting Brackets
-
- DIN-RACK-2U
- Din-Rail to 19" Rack Mount Adapter for all Din-Rail Mountable Products, 2U Height
-
- NDR-120-24
- 120W Single Output Industrial Din-Rail Power Supply, 24VDC Output
- IEEE 802.3 10Base-T Ethernet
- IEEE 802.3u 100Base-TX Fast Ethernet
- IEEE 802.3x Flow Control
- IEEE 802.3af/at Power over Ethernet
- 14,880pps for Ethernet Port
- 148,800pps for Fast Ethernet Port
- Back-Plane (Switching Fabric): 1.0Gbps
- Packet Throughput Ability (Full-Duplex): 1.488Mpps @ 64bytes
- Unit weight : 1.68 lbs
- Shipping weight : 2.0 lbs
- FCC Part 15 Subpart B Class A
- CE EN 55032 Class A
- EN 61000-6-4 Class A
- CE EN 55024
- EN 61000-6-2
- IEC61000-4-2 (ESD)
- IEC61000-4-3 (RS)
- IEC61000-4-4 (EFT)
- IEC61000-4-5 (Surge)
- IEC61000-4-6 (CS)
- IEC61000-4-8 (Magnetic Field)
- Free Fall: IEC60068-2-32
- Shock: IEC60068-2-27
- Vibration: IEC60068-2-6